Zeiss AxioCam MRc5 Manuel de service

Naviguer en ligne ou télécharger Manuel de service pour Mesure, test et contrôle Zeiss AxioCam MRc5. Zeiss AxioCam MRc5 Technical data Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 80
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
AxioCam MRc5
Installation + Reference - 10.2003
000000-1256-586
Number of this manual: B 48-0028 e
Date of issue: 05.2003
Date of the last revision/update: 10.2003
Vue de la page 0
1 2 3 4 5 6 ... 79 80

Résumé du contenu

Page 1 - AxioCam MRc5

AxioCam MRc5 Installation + Reference - 10.2003 000000-1256-586 Number of this manual: B 48-0028 e Date of issue: 05.2003 Date of the last revision/

Page 2

Installation of the AxioCam MRc5 2 B 48-0028 e 10.2003 Limitation of liability No warranty shall be assumed by Carl Zeiss during the warranty period

Page 3

Installation of the AxioCam MRc5 AxioCam MRc5 Installation + Reference 3 General notes Please ensure the notes described below are adhered to when se

Page 4 - 27.10.2003

Installation of the AxioCam MRc5 4 B 48-0028 e 10.2003 Backup copies We strongly recommend that all users save the data they create, such as images,

Page 5 - Table of Contents

Installation of the AxioCam MRc5 AxioCam MRc5 Installation + Reference 5 Recommended hardware and software  Xeon workstation 2 GHz or faster  1 G

Page 6

Installation of the AxioCam MRc5 6 B 48-0028 e 10.2003 Contents of Delivery  AxioCam MRc5 camera head  FireWire data cable (6-pin to 6-pin) for

Page 7

Installation of the AxioCam MRc5 AxioCam MRc5 Installation + Reference 7 1.3 Setting up the Camera System The standardized FireWire interface allows

Page 8 - IMPORTANT NOTE

Installation of the AxioCam MRc5 8 B 48-0028 e 10.2003 The table below provides an overview of the order numbers of the accessories: Accessory Order

Page 9

Installation of the AxioCam MRc5 AxioCam MRc5 Installation + Reference 9 Operating the AxioCam MRc5 on a PC using the FireWire PCI bus interface card

Page 10 - 2 B 48-0028 e 10.2003

Installation of the AxioCam MRc5 10 B 48-0028 e 10.2003 FireWire PCI bus interface card To ensure that power is supplied to the AxioCam MRc5, n

Page 11

Installation of the AxioCam MRc5 AxioCam MRc5 Installation + Reference 11 Connecting the camera to the PC Lay the data cable carefully between the c

Page 12 - 4 B 48-0028 e 10.2003

Carl Zeiss Vision draws the User's attention to the fact that the information and references contained in these documents may be subject to techn

Page 13

Installation of the AxioCam MRc5 12 B 48-0028 e 10.2003 Operating the AxioCam MRc5 on a PC with onboard FireWire interface Connecting the camera to

Page 14 - Camera, data cable

Installation of the AxioCam MRc5 AxioCam MRc5 Installation + Reference 13  The AxioCam MRc5 has been designed for continuous operation. During opera

Page 15

Installation of the AxioCam MRc5 14 B 48-0028 e 10.2003 For installation of the FireWire PCcard (CardBus) interface card, please also take into acc

Page 16 - 8 B 48-0028 e 10.2003

Installation of the AxioCam MRc5 AxioCam MRc5 Installation + Reference 15 The following components are required:  FireWire hub with power supply (o

Page 17

Installation of the AxioCam MRc5 16 B 48-0028 e 10.2003 Operating the AxioCam MRc5 on a notebook with onboard FireWire interfaces Connecting the cam

Page 18 - 10 B 48-0028 e 10.2003

Installation of the AxioCam MRc5 AxioCam MRc5 Installation + Reference 17 Connecting the AxioCam MRc5 to the onboard FireWire interface of the n

Page 19

Installation of the AxioCam MRc5 18 B 48-0028 e 10.2003 Mounting the camera onto the microscope To mount the camera onto your microscope’s TV port,

Page 20 - 12 B 48-0028 e 10.2003

Installation of the AxioCam MRc5 AxioCam MRc5 Installation + Reference 19 Second FireWire socket This FireWire socket may be used to cascade FireWire

Page 21

Installation of the AxioCam MRc5 20 B 48-0028 e 10.2003 1.4 Installing the Driver Software In order to operate the AxioCam MRc5 the AxioVision softw

Page 22 - 14 B 48-0028 e 10.2003

Installation of the AxioCam MRc5 AxioCam MRc5 Installation + Reference 21  When installing the components it is possible that some of the files to b

Page 23

Safety Refer to the safety notes and instructions in the manuals of all necessary devices (e.g. microscope peripherals, cameras, computers, computer

Page 24 - 16 B 48-0028 e 10.2003

Installation of the AxioCam MRc5 22 B 48-0028 e 10.2003 This section describes installation using the hardware wizard. If you want to update the cam

Page 25

Installation of the AxioCam MRc5 AxioCam MRc5 Installation + Reference 23 Select the option Search for a suitable driver for my device (recommende

Page 26 - Function indicator

Installation of the AxioCam MRc5 24 B 48-0028 e 10.2003 Under Windows 2000 Professional this dialog window is displayed. Click Yes to continue. Un

Page 27 - Expansion socket

Installation of the AxioCam MRc5 AxioCam MRc5 Installation + Reference 25 Installing the camera driver using the setup program NOTE:  For installat

Page 28 - 20 B 48-0028 e 10.2003

Installation of the AxioCam MRc5 26 B 48-0028 e 10.2003 If the automatic start function has been switched off on your system (Autorun) you must star

Page 29

Installation of the AxioCam MRc5 AxioCam MRc5 Installation + Reference 27 Under Windows 2000 Professional this dialog window will be displayed during

Page 30 - 22 B 48-0028 e 10.2003

Installation of the AxioCam MRc5 28 B 48-0028 e 10.2003 Start the systems Device Manager to check the installation:  Click Start ⇒ Settings ⇒ Contr

Page 31

Installation of the AxioCam MRc5 AxioCam MRc5 Installation + Reference 29 How to correct the driver entry in the device manager NOTE:  In this chap

Page 32 - 24 B 48-0028 e 10.2003

Installation of the AxioCam MRc5 30 B 48-0028 e 10.2003  The property page General opens. In this case, reinstall the AxioCam MRc5 using the inst

Page 33

Installation of the AxioCam MRc5 AxioCam MRc5 Installation + Reference 31 After the camera driver has been installed and (depending on the operating

Page 34 - 26 B 48-0028 e 10.2003

Revision / Update Information 27.10.2003 Installation adapted from Product CD 07.2003 to the installation of the product CD number 15 of October 2003

Page 35

Installation of the AxioCam MRc5 32 B 48-0028 e 10.2003 Resetting the AxioCam MRc5 firmware If the color of the LED on the back of the AxioCam MRc5

Page 36 - 28 B 48-0028 e 10.2003

Installation of the AxioCam MRc5 AxioCam MRc5 Installation + Reference 33 1.5 Notes on Maintenance Camera Electronic Camera, interface and power supp

Page 37

Image Acquisition with the AxioCam MRc5 34 B 48-0028 e 10.2003 2 Image Acquisition with the AxioCam MRc5 2.1 General The AxioCam MRc5 is a professi

Page 38 - 30 B 48-0028 e 10.2003

Image Acquisition with the AxioCam MRc5 AxioCam MRc5 Installation + Reference 35 2.2 Quick Guide to the First Image with AxioVision and AxioCam MRc5

Page 39

Image Acquisition with the AxioCam MRc5 36 B 48-0028 e 10.2003 The Workflow Standard Live starts and closes the live window. Show live window prope

Page 40 - 32 B 48-0028 e 10.2003

Image Acquisition with the AxioCam MRc5 AxioCam MRc5 Installation + Reference 37 Step by step to the first image  Select the camera you want to use

Page 41

Image Acquisition with the AxioCam MRc5 38 B 48-0028 e 10.2003 Here you can see the settings for the display of the image like Brightness, Contrast

Page 42 - 34 B 48-0028 e 10.2003

Image Acquisition with the AxioCam MRc5 AxioCam MRc5 Installation + Reference 39 Make changes for the camera settings on the following controls:  Th

Page 43

Image Acquisition with the AxioCam MRc5 40 B 48-0028 e 10.2003  Move the sliders GammaContrastBrightnessup or down to adjust the image. Good color

Page 44 - 36 B 48-0028 e 10.2003

Image Acquisition with the AxioCam MRc5 AxioCam MRc5 Installation + Reference 41  Captions and markings can be inserted using the Annotations window

Page 45

Table of Contents AxioCam MRc5 Installation + Reference i Table of Contents IMPORTANT NOTE...

Page 46 - 38 B 48-0028 e 10.2003

Image Acquisition with the AxioCam MRc5 42 B 48-0028 e 10.2003 2.3 Adjust Property Page This property page contains a summary of the most important

Page 47

Image Acquisition with the AxioCam MRc5 AxioCam MRc5 Installation + Reference 43 Exposure The camera’s exposure time can be adjusted to the lighting

Page 48 - 40 B 48-0028 e 10.2003

Image Acquisition with the AxioCam MRc5 44 B 48-0028 e 10.2003 A setting of 200% means that 200% of the exposure time set in the display window or m

Page 49

Image Acquisition with the AxioCam MRc5 AxioCam MRc5 Installation + Reference 45 White Balance In order to achieve a color display which is neutral a

Page 50 - 42 B 48-0028 e 10.2003

Image Acquisition with the AxioCam MRc5 46 B 48-0028 e 10.2003 Color adjustment Clicking on the buttons and allows you to change the weighting o

Page 51

Image Acquisition with the AxioCam MRc5 AxioCam MRc5 Installation + Reference 47 If an image is underexposed, the histogram does not reach the right-

Page 52 - Automatic exposure

Image Acquisition with the AxioCam MRc5 48 B 48-0028 e 10.2003 2.4 Frame Property Page The Frame property page can be used to select a frame for th

Page 53

Image Acquisition with the AxioCam MRc5 AxioCam MRc5 Installation + Reference 49 reduce the amount of data. The camera will always acquire a color im

Page 54 - Color adjustment

Image Acquisition with the AxioCam MRc5 50 B 48-0028 e 10.2003 Selectable resolution in "Quality" mode ("Iinterlaced") – recomme

Page 55

Image Acquisition with the AxioCam MRc5 AxioCam MRc5 Installation + Reference 51 Binning The process of Binning ensures that the information in neigh

Page 56 - 48 B 48-0028 e 10.2003

Table of Contents ii B 48-0028 e 10.2003 Installing the camera driver using the setup program ... 25 How to correct the driver entry

Page 57 - Acquisition modes

Image Acquisition with the AxioCam MRc5 52 B 48-0028 e 10.2003 Frame In this field you can specify whether the frame or the entire area of the senso

Page 58 - 50 B 48-0028 e 10.2003

Image Acquisition with the AxioCam MRc5 AxioCam MRc5 Installation + Reference 53 2.5 General Property Page On this property page you enter the basic

Page 59 - Resulting file size

Image Acquisition with the AxioCam MRc5 54 B 48-0028 e 10.2003 The disadvantage of this technique, however, is that noise is greatly intensified, an

Page 60 - 52 B 48-0028 e 10.2003

Image Acquisition with the AxioCam MRc5 AxioCam MRc5 Installation + Reference 55 For this calibration process make sure that the camera is viewing a

Page 61

Image Acquisition with the AxioCam MRc5 56 B 48-0028 e 10.2003 Shutter Control Via a supplementary cable the AxioCam MRc5 offers a TTL control pulse

Page 62 - 54 B 48-0028 e 10.2003

Image Acquisition with the AxioCam MRc5 AxioCam MRc5 Installation + Reference 57 Enhance Color: Activating this check box enables you to switch the c

Page 63

Image Acquisition with the AxioCam MRc5 58 B 48-0028 e 10.2003  Deactivating the focus bar.  Deactivating the live image scaling (1:1 representati

Page 64 - 56 B 48-0028 e 10.2003

Image Acquisition with the AxioCam MRc5 AxioCam MRc5 Installation + Reference 59 This adjusts the display characteristic curve automatically for an o

Page 65

Image Acquisition with the AxioCam MRc5 60 B 48-0028 e 10.2003 You can now select the area to be displayed by dragging the black rectangles along

Page 66 - 58 B 48-0028 e 10.2003

Image Acquisition with the AxioCam MRc5 AxioCam MRc5 Installation + Reference 61 Best Fit calculates in the current histogram the values which exclud

Page 67

Table of Contents AxioCam MRc5 Installation + Reference iii Gamma setting ...

Page 68 - 60 B 48-0028 e 10.2003

Image Acquisition with the AxioCam MRc5 62 B 48-0028 e 10.2003 Recommended camera settings Activate the Enhance Color check box on the General prope

Page 69

Image Acquisition with the AxioCam MRc5 AxioCam MRc5 Installation + Reference 63 2.8 Background Information Gamma setting This setting is required to

Page 70 - 62 B 48-0028 e 10.2003

Image Acquisition with the AxioCam MRc5 64 B 48-0028 e 10.2003 In the case of fluorescence, however, only very narrow-band light is emitted. This is

Page 71

Trouble Shooting AxioCam MRc5 Installation + Reference 65 3 Trouble Shooting If errors occur, check first the setup instructions of the camera. 3.1 S

Page 72 - 64 B 48-0028 e 10.2003

Trouble Shooting 66 B 48-0028 e 10.2003 3.2 Image Quality  Sudden jolt, vibration or moving objects  If the microscope is jolted whilst you are t

Page 73 - 3 Trouble Shooting

Technical Data AxioCam MRc5 Installation + Reference 67 4 Technical Data 4.1 AxioCam MRc5 Number of pixels: 2584 (H) x 1936 (V) = 5 Megapixels Digit

Page 74 - 66 B 48-0028 e 10.2003

Technical Data 68 B 48-0028 e 10.2003 Pixel size: 3,4 µm x 3,4 µm Sensor size: 8,7 mm x 6,6 mm entspricht 2/3" CCD Sensor: ICX 282, Interlin

Page 75 - 4 Technical Data

Technical Data AxioCam MRc5 Installation + Reference 69 4.2 Spectral Sensitivity Standardized at maximum amplitude It does not make sense to operate

Page 76

Index AxioCam MRc5 Installation + Reference I Index 1 12-bit images 59 A acquisition delay 56 acquisition modes 49 Adjust property page 42 automa

Page 77 - 4.2 Spectral Sensitivity

Index II B 48-0028 e 10.2003 How to correct the driver entry in the device manager 29 I image acquisition 34 image frame 48 image orientation 54

Page 78

IMPORTANT NOTE FireWire (IEEE 1394) Interface The FireWire (IEEE 1394) interface is defined as a "hot plugging" interconnection, i.e. peri

Page 79 - II B 48-0028 e 10.2003

Index AxioCam MRc5 Installation + Reference III system requirements 4 T technical data 67 toolbars 64 trouble shooting 65 U underexposure 47 W w

Page 80

Installation of the AxioCam MRc5 AxioCam MRc5 Installation + Reference 1 1 Installation of the AxioCam MRc5 The AxioCam MRc5 is a professional camer

Commentaires sur ces manuels

Pas de commentaire